Storage of sputum in cetylpyridinium chloride, OMNIgene.SPUTUM, and ethanol is compatible with molecular tuberculosis diagnostic testing

Sanoussi, C.N., de Jong, B.C., Affolabi, D., Meehan, C.J. ORCID: 0000-0003-0724-8343, Odoun, M. and Rigouts, L., 2019. Storage of sputum in cetylpyridinium chloride, OMNIgene.SPUTUM, and ethanol is compatible with molecular tuberculosis diagnostic testing. Journal of Clinical Microbiology, 57 (7): e00275-19. ISSN 0095-1137

Full text not available from this repository.

Abstract

We compared cetylpyridinium chloride (CPC), ethanol (ETOH), and OMNIgene.SPUTUM (OMNI) for 28-day storage of sputum at ambient temperature before molecular tuberculosis diagnostics. Three sputum samples were collected from each of 133 smear-positive tuberculosis (TB) patients (399 sputum samples). Each patient’s sputum was stored with either CPC, ETOH, or OMNI for 28 days at ambient temperature, with subsequent rpoB amplification targeting a short fragment (81 bp, GeneXpert MTB/RIF [Xpert]) or a long fragment (1,764 bp, in-house nested PCR). For 36 patients, Xpert was also performed at baseline on all 108 fresh sputum samples. After the 28-day storage (D28), Xpert positivity did not significantly differ between storage methods. In contrast, higher positivity for rpoB nested PCR was obtained with OMNI (n = 125, 94%) than with ETOH (n = 114, 85.7%; P = 0.001). Smears with scanty acid-fast bacilli (AFB) had lower rpoB PCR positivity with ETOH storage (n = 10, 41.7%) than with CPC (n = 16, 66.7%; difference, 25%; 95% confidence interval [CI], 3.5 to 46.5; P = 0.031) or OMNI (n = 16, 69.6%; difference, 26.1%; 95% CI, 3.8 to 48.4; P = 0.031), with no difference between CPC and OMNI. Poststorage, the threshold cycle (CT) values significantly decreased compared to those prestorage with ETOH (difference, −1.1; 95% CI, −1.6 to −0.6; P = 0.0001) but not with CPC (P = 0.915) or OMNI (P = 0.33). For one patient’s ETOH- and CPC-stored specimens with a CT of <10, Xpert gave results of rifampin false resistant at D28, which was resolved by repeating Xpert on a 1/100 diluted specimen. In conclusion, 28-day storage of sputum in OMNI, CPC, or ETOH at ambient temperature does not impact short-fragment PCR (Xpert), including for low smear grades. However, for long-fragment PCR, ETOH yielded a lower PCR positivity for low smear grades, while the performance of OMNI and CPC was excellent for all smear grades. (The study has been registered at ClinicalTrials.gov under registration number NCT02744469.)

Item Type: Journal article
Publication Title: Journal of Clinical Microbiology
Creators: Sanoussi, C.N., de Jong, B.C., Affolabi, D., Meehan, C.J., Odoun, M. and Rigouts, L.
Publisher: American Society for Microbiology
Date: 25 June 2019
Volume: 57
Number: 7
ISSN: 0095-1137
Identifiers:
NumberType
10.1128/jcm.00275-19DOI
1627060Other
Rights: This is an open-access article distributed under the terms of the Creative Commons Attribution 4.0 International license.
Divisions: Schools > School of Science and Technology
Record created by: Jonathan Gallacher
Date Added: 13 Dec 2022 09:07
Last Modified: 13 Dec 2022 09:07
URI: https://irep.ntu.ac.uk/id/eprint/47635

Actions (login required)

Edit View Edit View

Views

Views per month over past year

Downloads

Downloads per month over past year