Slattery, P., Wheat, J. ORCID: 0000-0002-1107-6452, Lizama, L.E.C., Gastin, P., Dascombe, B., Huynh, M. and Middleton, K., 2024. The repeatability of stride time variability, regularity, and long-range correlations. Gait and Posture, 114, pp. 257-262. ISSN 0966-6362
Text
2270221_Wheat.pdf - Post-print Full-text access embargoed until 19 October 2025. Download (243kB) |
Abstract
Background: Detrended fluctuation analysis (DFA) and sample entropy (SE) measure the long-term correlations and regularity of gait patterns, respectively, having previously been used to identify participants at risk of falling, previous history of injury, or patients with motor diseases. Since these measures are more sensitive to gait impairment than linear measures (e.g., the standard deviation [SD] of stride time), they can be potentially used in military medicine to identify soldiers at risk of injury. However, clinometric properties are yet to be established.
Research Question: What is the repeatability of DFA, SE, and traditional linear measures of stride time variability (SD and coefficient of variation [CV]) under various load and speed constraints?
Methods: Fourteen Australian Army trainee soldiers (age: 25.6 ± 5.9 y, height: 1.74 ± 0.08 m, body mass: 77.2 ± 15.1 kg, service: 1.5 ± 1.8 y) attended three sessions over two weeks, completing four 12-minute walking trials on an instrumented treadmill in each session. Participants walked with a combination of 0 kg or 23 kg loads at a self-selected or 5.5 km/h speed. Heel contacts from the right foot were identified using treadmill-embedded force plates. From 512 stride time intervals, linear (SD and CV), and non-linear (DFA and SE) measures were obtained. To assess the between-session repeatability, intraclass correlations (ICC 2,1) were employed.
Results and Significance: There was poor-to-moderate repeatability for the SD (ICC: 0.357–0.545) and CV (ICC: 0.371–0.529). DFA showed poor-to-moderate repeatability (ICC: 0.013–0.504), while SE had poor repeatability (ICC: 0.133–0.226). Previous studies have shown that differences of > 0.19 in DFA and > 0.66 in SE can differentiate between healthy and pathological gait. These values are greater than this study's reported standard error of measurement, indicating that clinically meaningful changes may still be detectable despite low repeatability.
Item Type: | Journal article | ||||||
---|---|---|---|---|---|---|---|
Publication Title: | Gait and Posture | ||||||
Creators: | Slattery, P., Wheat, J., Lizama, L.E.C., Gastin, P., Dascombe, B., Huynh, M. and Middleton, K. | ||||||
Publisher: | Elsevier | ||||||
Date: | October 2024 | ||||||
Volume: | 114 | ||||||
ISSN: | 0966-6362 | ||||||
Identifiers: |
|
||||||
Rights: | This is an open access article under the CC BY-NC license (https://creativecommons.org/licenses/by-nc/4.0/). | ||||||
Divisions: | Schools > School of Science and Technology | ||||||
Record created by: | Jonathan Gallacher | ||||||
Date Added: | 31 Oct 2024 11:36 | ||||||
Last Modified: | 31 Oct 2024 11:36 | ||||||
URI: | https://irep.ntu.ac.uk/id/eprint/52494 |
Actions (login required)
Edit View |
Views
Views per month over past year
Downloads
Downloads per month over past year