The repeatability of stride time variability, regularity, and long-range correlations

Slattery, P., Wheat, J. ORCID: 0000-0002-1107-6452, Lizama, L.E.C., Gastin, P., Dascombe, B., Huynh, M. and Middleton, K., 2024. The repeatability of stride time variability, regularity, and long-range correlations. Gait and Posture, 114, pp. 257-262. ISSN 0966-6362

[img] Text
2270221_Wheat.pdf - Post-print
Full-text access embargoed until 19 October 2025.

Download (243kB)

Abstract

Background: Detrended fluctuation analysis (DFA) and sample entropy (SE) measure the long-term correlations and regularity of gait patterns, respectively, having previously been used to identify participants at risk of falling, previous history of injury, or patients with motor diseases. Since these measures are more sensitive to gait impairment than linear measures (e.g., the standard deviation [SD] of stride time), they can be potentially used in military medicine to identify soldiers at risk of injury. However, clinometric properties are yet to be established.

Research Question: What is the repeatability of DFA, SE, and traditional linear measures of stride time variability (SD and coefficient of variation [CV]) under various load and speed constraints?

Methods: Fourteen Australian Army trainee soldiers (age: 25.6 ± 5.9 y, height: 1.74 ± 0.08 m, body mass: 77.2 ± 15.1 kg, service: 1.5 ± 1.8 y) attended three sessions over two weeks, completing four 12-minute walking trials on an instrumented treadmill in each session. Participants walked with a combination of 0 kg or 23 kg loads at a self-selected or 5.5 km/h speed. Heel contacts from the right foot were identified using treadmill-embedded force plates. From 512 stride time intervals, linear (SD and CV), and non-linear (DFA and SE) measures were obtained. To assess the between-session repeatability, intraclass correlations (ICC 2,1) were employed.

Results and Significance: There was poor-to-moderate repeatability for the SD (ICC: 0.357–0.545) and CV (ICC: 0.371–0.529). DFA showed poor-to-moderate repeatability (ICC: 0.013–0.504), while SE had poor repeatability (ICC: 0.133–0.226). Previous studies have shown that differences of > 0.19 in DFA and > 0.66 in SE can differentiate between healthy and pathological gait. These values are greater than this study's reported standard error of measurement, indicating that clinically meaningful changes may still be detectable despite low repeatability.

Item Type: Journal article
Publication Title: Gait and Posture
Creators: Slattery, P., Wheat, J., Lizama, L.E.C., Gastin, P., Dascombe, B., Huynh, M. and Middleton, K.
Publisher: Elsevier
Date: October 2024
Volume: 114
ISSN: 0966-6362
Identifiers:
NumberType
10.1016/j.gaitpost.2024.10.014DOI
2270221Other
Rights: This is an open access article under the CC BY-NC license (https://creativecommons.org/licenses/by-nc/4.0/).
Divisions: Schools > School of Science and Technology
Record created by: Jonathan Gallacher
Date Added: 31 Oct 2024 11:36
Last Modified: 31 Oct 2024 11:36
URI: https://irep.ntu.ac.uk/id/eprint/52494

Actions (login required)

Edit View Edit View

Views

Views per month over past year

Downloads

Downloads per month over past year