Real-time measurement of pelvis and trunk kinematics during treadmill locomotion using a low-cost depth-sensing camera: a concurrent validity study

Macpherson, T.W., Taylor, J., McBain, T., Weston, M. and Spears, I.R. ORCID: 0000-0003-4982-2841, 2016. Real-time measurement of pelvis and trunk kinematics during treadmill locomotion using a low-cost depth-sensing camera: a concurrent validity study. Journal of Biomechanics, 49 (3), pp. 474-478. ISSN 0021-9290

[img]
Preview
Text
14401_Spears.pdf - Post-print

Download (694kB) | Preview

Abstract

There is currently no suitable kinematic system for a large-scale prospective trial assessing risk factors of musculoskeletal disorders. A practical kinematic system is described which involves the use of a single low-cost depth-sensing camera for the real-time measurement of 3-dimensional linear and angular pelvic and trunk range-of-movement (ROM). The method is based on the creation and processing of dynamic point clouds taken from the posterior surface of the pelvis and trunk. Nine healthy participants performed 3 trials of treadmill locomotion when walking at self-selected speed (3.6–5.6 km/h), running at 70% (10.9–14.0 km/h) and 90% of maximal speed (14.0–18.0 km/h). Stride-by-stride linear and angular ROM data were captured concurrently using the single depth-sensing camera running at 30 Hz (KinectTM for Windows, Microsoft, USA) and a six-camera motion capture system at 100 Hz (Vicon MX13, Vicon Motion Systems, United Kingdom). Within subject correlation coefficients between the practical and criterion method ranged from very large to nearly perfect (r=0.87–1.00) for the linear ROM. Correlation coefficients for the angular ROM ranged from moderate to very large (r=0.41–0.80). The limits of agreement between the two systems for linear movements were ≤9.9 mm at all velocities of gait and ≤4.6° at all velocities of gait. The single camera system using depth-sensing technology is capable of capturing linear pelvic and trunk ROM during treadmill locomotion with reasonable precision when compared to the criterion method. Further improvements to the measurement of angles and validation across a wider population are recommended.

Item Type: Journal article
Publication Title: Journal of Biomechanics
Creators: Macpherson, T.W., Taylor, J., McBain, T., Weston, M. and Spears, I.R.
Publisher: Elsevier
Date: 8 February 2016
Volume: 49
Number: 3
ISSN: 0021-9290
Identifiers:
NumberType
10.1016/j.jbiomech.2015.12.008DOI
S0021929015007095Publisher Item Identifier
Divisions: Schools > School of Science and Technology
Record created by: Linda Sullivan
Date Added: 09 Aug 2019 15:24
Last Modified: 09 Aug 2019 15:24
URI: https://irep.ntu.ac.uk/id/eprint/37216

Actions (login required)

Edit View Edit View

Views

Views per month over past year

Downloads

Downloads per month over past year