Marker based and markerless motion capture for equestrian rider kinematic analysis: a comparative study

Cameron-Whytock, H, Divall, H ORCID logoORCID: https://orcid.org/0009-0001-4071-4281, Lewis, M and Apps, C ORCID logoORCID: https://orcid.org/0000-0002-7354-0003, 2025. Marker based and markerless motion capture for equestrian rider kinematic analysis: a comparative study. Journal of Biomechanics, 186: 112728. ISSN 0021-9290

[thumbnail of 2437047_Apps.pdf]
Preview
Text
2437047_Apps.pdf - Published version

Download (9MB) | Preview

Abstract

The study hypothesised that a markerless motion capture system can provide kinematic data comparable to a traditional marker-based system for riders mounted on a horse. The objective was to assess the markerless system’s accuracy by directly comparing joint and segment angle measurements taken during walking and trotting with those obtained from a marker-based system. Ten healthy adult participants performed five dynamic trials during walking and trotting. A twelve-camera marker-based system and eight-camera 2D video-based system were synchronised. Three-dimensional hip, knee, shoulder and elbow joint angles, and the global trunk and pelvis angle were computed for comparison between the two systems. To assess the error between systems, the root mean square difference (RMSD) was averaged across each gait cycle and statistical parametric mapping (SPM) paired t-tests were applied. The sagittal trunk angle had the lowest RMSD of 2.0° and elbow rotation had the highest RMSD of 19°, with the same values for walking and trotting. SPM indicated increased hip flexion (0–100 %, p < 0.001) and elbow flexion (24–47 %, p = 0.03; 63–100 %, p < 0.001) in the walking gait cycle for the markerless system. A lack of joint range of motion and obscured medial limbs during walking whilst mounted on horses may cause increased offsets for markerless data in equestrian riders. No significant differences were found for the transverse plane, yet there tended to be increased RMSD. This lack of consistency suggests results from the transverse plane in equestrian riders should be interpreted with caution. Study findings indicate that markerless technology has the potential to be a suitable alternative to marker-based systems for assessment of equestrian riders, dependent on the segment/joint angle of interest and the level of acceptable error. These results indicate that markerless systems can effectively be utilised for rider biofeedback, though their application may be limited for specific joint analyses.

Item Type: Journal article
Publication Title: Journal of Biomechanics
Creators: Cameron-Whytock, H., Divall, H., Lewis, M. and Apps, C.
Publisher: Elsevier
Date: June 2025
Volume: 186
ISSN: 0021-9290
Identifiers:
Number
Type
10.1016/j.jbiomech.2025.112728
DOI
S0021929025002404
Publisher Item Identifier
2437047
Other
Rights: © 2025 the author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
Divisions: Schools > School of Science and Technology
Record created by: Jonathan Gallacher
Date Added: 08 May 2025 08:33
Last Modified: 08 May 2025 08:33
URI: https://irep.ntu.ac.uk/id/eprint/53552

Actions (login required)

Edit View Edit View

Statistics

Views

Views per month over past year

Downloads

Downloads per month over past year